Customer Service Bulletin
SCHWINN FITNESS
1 of 2
637-1491 Rev: A
Watt Differences & New Brake Rod Assembly
Schwinn AC Performance Plus
Symptom:
AC Performance Plus WITHOUT watts computer (MPower console V2):
In some rare cases, a slight amount of resistance may be noticeable on the pedals even with the
resistance knob adjusted to the zero resistance position.
AC Performance Plus WITH watts computer (MPower console V2):
Less watts shown on the MPower console than felt on the pedals.
Root Cause:
In some instances the resistance/brake rod used on the AC Performance Plus may be too short causing the brake
carriage to stop BEFORE it reaches the true zero position (Fig. 1).
All bikes with serial number 100178DAY12520198 and newer come with the new resistance/brake rod.
Fig. 1
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Customer Service Bulletin

Customer Service Bulletin SCHWINN FITNESS 1 of 2 637-1491 Rev: A Watt Differences & New Brake Rod Assembly Schwinn AC Performance Plus

Page 2

Customer Service Bulletin SCHWINN FITNESS 2 of 2 637-1491 Rev: A Resolution: 1. Replace the current brake rod with a new one (PN: 000-0098)