7TROUBLESHOOTINGConsole shuts off (enters sleep mode) while in useBASIC TROUBLESHOOTING6. Problem:Solution: A. Check data cable integrity. All cable
TROUBLESHOOTING8BASIC TROUBLESHOOTINGFan (if equipped) will not turn on or will not turn off7. Problem:Solution: A. Check data cable integrity. All w
9TROUBLESHOOTINGUnit rocks/does not sit levelBASIC TROUBLESHOOTING8. Problem:Solution: A. Check leveler adjustment. Leveling feet may be turned in or
TROUBLESHOOTING10ADVANCED TROUBLESHOOTINGNo display/Unit will not turn onA1. Problem:Solution: A. Check A/C adapter (assumes electrical outlet is OK).
11TROUBLESHOOTING C. Check upper wiring harness (assumes A/C adapter is OK, and no voltage is present at the end of the upper wiring harness). Remove
TROUBLESHOOTING12ADVANCED TROUBLESHOOTINGResistance does not change (assumes unit powers up and otherwise functions normally)A2. Problem:Solution: A.
13TROUBLESHOOTINGADVANCED TROUBLESHOOTINGDrive train click/tick noise once per full crank revolutionA3. Problem:Solution: A. Check crank/pulley assemb
TROUBLESHOOTING14Noise multiple times per revolution or once per 1.5 revo-lution.A4. Problem:Solution: A. Check belt. Remove shrouds (see A6). Visua
15TROUBLESHOOTINGADVANCED TROUBLESHOOTINGA5. Problem:Refer to Figures B and C to locate the four pivots (two on each side of the machine).A. Loosen ha
TROUBLESHOOTING16ADVANCED TROUBLESHOOTINGSomething wrong with the motor, flywheel, RPM sensor, or other internal componentsA6. Problem:Solution:Access
©2006. Nautilus, Inc. All Rights Reserved. Schwinn is a registered trademark. Nautilus, Inc., World Headquarters, 16400 SE Nautilus Dr., Vancouver, WA
17IMPORTANT CONTACT NUMBERS OFFICES IN THE UNITED STATES: E-mail: [email protected]• NAUTILUS INNOVATION CENTERNautilus, Inc. 1886 Pr
SERVICE MANUAL PN 001-6987 REV B (03/07) SCHWINN RETAIL ELLIPTICALSService ManualThis manual applies to the following models:426430 431450
1CONTENTS Table of ContentsReading the Serial Number ...2Troubleshooting ...
READING THE SERIAL NUMBER2SCHWINN ELLIPTICAL SERIAL NUMBERSThe serial number can be located on the underside of the machine base. The below instructi
3TROUBLESHOOTINGNo display/partial display/unit will not turn onBASIC TROUBLESHOOTING1. Problem:Solution:A. Make sure the unit is plugged into a funct
TROUBLESHOOTING4Unit operates but Contact HR not displayedBASIC TROUBLESHOOTING2. Problem:Solution:Note: Sensors may have difficulty with dried out or
5TROUBLESHOOTINGUnit operates but Telemetric HR not displayedBASIC TROUBLESHOOTING3. Problem:Solution:A. Check for interference. Try moving the unit
TROUBLESHOOTING6No speed/RPM readingBASIC TROUBLESHOOTING5. Problem:Solution: A. Check data cable integrity. All wires in the cable should be intact.